Perceptual
Level of Detail
Our Level of Detail Generator (LOD Generator) builds level-of-detail chains for textured 3D models and supports PBR materials, rigs and animations. Each level is optimised for perceptual fidelity: its renders are compared with those of the source model using the FLIP image-difference metric, including materials and textures.
Based on Master’s thesis topic proposed and supervised by Dmitrii Klepikov and Mikhail Dereviannykh


Dense, irregular meshes
The models shown on this page, except the chest, were generated with an image-to-3D model (TRELLIS). Each has about 470,000 to 500,000 triangles, no clean edge loops and its textures in one automatically unwrapped atlas. Meshes like these are hard for edge-collapse decimation: on the ten featured models below, Blender Decimate’s error is 3.8 to 6.3 times that of the LOD Generator. The benchmark in the results section covers 110 models, 100 of them generated the same way; over all of them the factor is 4.0 to 5.3.
The LOD Generator and a reference tool, side by side
Both halves share one camera and always show the same level. Drag to orbit, scroll or pinch to zoom. Only the two meshes on screen are downloaded.
The 3D viewer loads when it comes into view.
Requires WebGL 2.
is the benchmark error of the level (deployment cameras, sphere set; lower is better); is the ratio of the reference tool’s error to the LOD Generator’s at its triangle count. The viewer shows the sphere-set meshes, since it can be orbited below the model. For each gallery model (after the featured ones) the viewer shows the best of three generation runs (lowest mean FLIP over its five levels); the featured models show the first run. All statistics on this page average the three runs. For web delivery every model, from every tool, is compressed with identical settings; the error values were measured on the uncompressed models.
Animated assets
An animated asset is reduced once for all of its poses: surfaces that the animation brings into view, such as the interior behind a lid, a door or a drawer, are kept. The chest below plays its animation (lid, doors, drawers and lock) on both sides; the level and the reference tool can be switched while it runs.
The 3D viewer loads when it comes into view.
Requires WebGL 2.
in this section is the posed error: the same error measure, evaluated at three held-out times of the animation clip, from cameras around all poses of the source model (sphere set); is the reference tool’s error relative to the LOD Generator’s at its triangle count. The chest (“Chest”, Korean chest 1937.20.0002, Världskulturmuseerna) is in the public domain (CC0); it is one of the 110 benchmark assets.
Where the error is
Path-traced renders of the benchmark figures, at matched triangle counts. The FLIP map shows the per-pixel difference to the source render: dark means no visible difference, bright means a clearly visible one.
Error at matched triangle counts
110 benchmark assets: 100 buildings drawn at random from the asset library of a strategy game in development, generated with TRELLIS like the models above, and ten production assets (three buildings, a ship, two trees, two skinned characters, a skinned scooter and a chest with node animation). Each is reduced to five levels and evaluated in two camera envelopes. The tables and charts below reproduce the report’s tables.
Median error ratio per tool and level
at the LOD Generator’s triangle count, where gen denotes the LOD Generator; means the tool’s mesh has more error. Median over the rows the tool can reach, with the 95 % asset-clustered bootstrap interval in brackets.
Verdict per comparison
A row is one asset, camera set and level. The LOD Generator is better or worse when the difference exceeds the row’s noise band; a miss is a row where the tool cannot produce that few triangles.
Triangles at equal error
: how many times the LOD Generator’s triangle count a tool needs to match its error. Lower bound of the median over all values; at LOD 1 no tool level lies above the LOD Generator’s count, so there by construction.
Show as table
Time to generate a five-level chain for 10 million triangle mesh
Wall-clock time from reading the source model to having written all five levels; median of three runs per tool (Blender: one run).
Rate–distortion curves
Error against triangle count for one model, both axes logarithmic. LOD Generator: mean of three seeds with the range across seeds. Hollow marks: a tool level that stopped above the count it was asked for.
How the error is measured
A level and the source model are rendered under identical physically based shading, with textures, alpha masking and alpha blending, from the same cameras. The studio environment light and its reflections are occluded by the model itself (ray-traced), and MASK materials are alpha-tested on the full-resolution texture (mip 0). None of the evaluation cameras is available to the LOD Generator when it builds its meshes.
Mean FLIP over the covered pixels
FLIP (Andersson et al., 2020) gives a per-pixel perceptual difference in . are the pixels covered by the source model or by the level in view ; and are the renders of the source and of the level.
One score per level: pixel-weighted root mean square
Over views, each view is weighted by the number of pixels the source model covers, corrected by the framing scale so that an object drawn larger does not weigh more. Lower is better.
Error ratio at matched triangle counts
The index gen denotes the LOD Generator. Each reference tool is run with its triangle count as its target (accepted within ±1 %). Its error at the LOD Generator’s count is interpolated linearly in against between its two neighbouring levels; nothing is extrapolated beyond 1 %.
Triangles at equal error
Read by inverse interpolation on the tool’s curve. Where even the tool’s highest level has more error than the LOD Generator, only a lower bound is known; such censored values are reported as bounds, not mixed with exact ones.
Verdict: noise band from three seeds
The LOD Generator runs three times with different random seeds. The noise band of a row is twice the standard error of its three per-seed values of , and at least 0.02. The row counts as better when exceeds 1 by more than the band, as worse when it falls below 1 by more than the band, and as tied otherwise.
Medians, geometric means, intervals
Summaries over many rows are the median and the geometric mean of ; the geometric mean suits ratios, since a tool twice as good and one twice as bad average to 1. 95 % confidence intervals come from an asset-clustered percentile bootstrap: whole assets are resampled with replacement, 10,000 draws with a fixed seed.
Setup
- Camera envelopes
- Hemisphere: cameras on or above the horizon, the underside is never seen. Sphere: cameras from all directions. Each envelope has its own LOD Generator meshes, reference meshes and cameras; nothing is pooled across them.
- Camera sets
- Lattice: 12 directions at 512 × 512 px. Deployment: 12 cameras of varying elevation, distance and field of view. Close-up: 6 directions at 2048 × 2048 px. Posed: the lattice with every animation clip sampled at three times (skinned and animated assets).
- Levels
- Five levels at 50 %, 25 %, 12.5 %, 6.25 % and 3 % of the source triangle count. Triangle counts are drawn triangles, including every instance.
- Reference tools
- Blender 5.2.2, Decimate modifier in collapse mode; meshoptimizer 1.3 (tag v1.3): simplify, simplifyWithAttributes, SimplifyPermissive, simplifySloppy, and on the ten production assets also SimplifyPermissive and simplifyWithAttributes with SimplifyPreserveFolds. Each tool is deterministic and was run once per asset, envelope and level.
- Misses
- When a tool cannot get down to the LOD Generator’s count and stops above it, the row is a miss. Misses have no ; they are excluded from medians and verdict counts and reported separately.
- Version and date
- LOD Generator 0.3. All 110 models were measured on 14 October 2026 with the same binary and protocol. Charts on this page reproduce the tables of the pooled benchmark report.
Contact
Questions about the LOD Generator or the benchmark? Write or call Calcuflow GmbH.
